Section II highlights the
common planning requirements which are to be complied in a DC submission.
If any of the requirements cannot be complied with, the QPs must list
down the deviations in Annex 1; and attach it to the application form.
| Nos |
Items |
Please tick accordingly |
Remarks |
| Complied With |
Not Applicable |
| 1 |
Road Line & Drainage Interpretation plans
To declare and endorse on the proposal plans that the Road reserve lines and
Drainage reserve lines as indicated on plans are in accordance with respective
interpretation plans For details please refer to
EDA WebPages) |
|
|
|
| 2 |
Do not show the detailed technical information and codes of practice notes
of other government agencies like the NEA, NParks, FSSD & LTA on the DC
plans (For details, please refer to Circular No:
URA/PB/2008/10-DCD
dated 5 May 08) |
|
|
|
| 3 |
Fees The required processing fees is payable by cheque. The cheque
is to be submitted to URA within 2 working days from the date of submission.
|
|
|
|
| 4 |
Owner's/owners' consent
| - |
To declare the owner's or owners' consent
for the development application and append the endorsement
on owner's consent to all CAD drawings.
|
| - |
To furnish scanned copy of authorization
letter from applicant. |
|
|
|
|
| 5 |
Land Title Declaration
| - |
To furnish scanned copy of Land Title Declaration Form |
(Soft copy can be downloaded from our
website
for your submission)
|
|
|
Applicable to submission under DC3, DC12 and DC24 |
| 6 |
The site boundary and all plot boundary are verged red and with dimensions
& plot areas indicated on plans. |
|
|
|
| 7 |
Proposed plot ratio, equivalent plot ratio & gross floor area are
indicated on forms/and plans. |
|
|
|
| 8 |
All boundary and building setbacks (front, side & rear/upper storey rear)
are indicated on plans. |
|
|
|
| 9 |
All building plots, communal open space & parcels of land for vesting such
as road widening, drainage reserve, electric substation, septic tank, etc
are shown as separate plots on plans. Please ensure separate plot is
assigned to drainage reserve only when vesting is at CSC stage,
otherwise, no separate plot is needed. |
|
|
|
| 10 |
All plot areas, widths & depths are indicated on the site plan and with
a legend for two or more plots. |
|
|
|
| 11 |
Site coverage is indicated on forms and/or plans. |
|
|
|
| 12 |
Details of each building/types of building, number of storeys, the scale used
and the highest height in metres AMSL are indicated on plan. |
|
|
|
| 13 |
Communal open space indicated on forms and/ or plans. |
|
|
Applicable to strata landed development only |
| 14 |
Existing land profile indicated & highlighted in colour.
Proposed land profile indicated. (Where the proposed land profile is the same as
the existing land profile, it should also be annotated on plan. |
|
|
For all cross-section and elevations |
| 15 |
Existing ground levels for the subject site and adjoining sites immediately
across the common boundaries & proposed platform levels indicated on
site plans and 1st storey plans. |
|
|
|
| 16 |
Proposal site on undulating grounds is accompanied by Topography Plan. |
|
|
|
| 17 |
Details of fencing shown on the submission plans. |
|
|
|
| 18 |
Retaining walls if any, are shown on the submission plans. |
|
|
|
| 19 |
Topographical plans with contours extending to a width of one metre beyond the
side of development fronting the water course, including spot levels of
drainage reserve land up to the edge of the bank. |
|
|
|
| 20 |
Typical cross-sections showing the proposed development of the area between
the site and the drainage reserve or coastal area, including the existing
and proposed ground levels. |
|
|
Applicable to proposals affected by waterbodies |
| 21 |
Clearance from Drainage Department, ENV for integration of linear body
as part of the development/modification of the edge profile of the linear
body is attached. |
|
|
|
| 22 |
Engineer's certification on the slope is attached. |
|
|
|
| 23 |
The project title is suitably appended to reflect more accurately the nature
of the submission and highlight the predominant use only. |
|
|
|
| 24 |
Buffer requirements are indicated on plans. |
|
|
*Refer to Buffer Standards |
| 25 |
The tenure of land is indicated on plans. |
|
|
|
| 26 |
North point to face upwards on plan. |
|
|
|
| 27 |
2m wide planting strip along the boundary indicated on plans. |
|
|
Except for landed housing developments &
periphery of industrial developments |
| 28 |
Access arrangement indicated on plans requirements. |
|
|
|
| 29 |
A massing model of scale 1:500 |
|
|
Applicable to URA Sales Projects except for industrial &
warehouse developments |
| 30 |
Building Finishes for developments within Central Area and
selected sites outside Central Area as required in the Sales Technical Condition |
|
|
|
| 31 |
Air-conditioning ledges and air conditioning
condensers, if any, are shown on the submission plans. |
|
|
Applicable to landed housing developments only |
| 32 |
Computation of the percentage of balcony perimeter opening |
|
|
Applicable only to flats/condominium and hotel developments as
well as the residential component of mixed use developments
|
| 33 |
Details of balcony screen design & retracting system shown on
submission plans |
|
|
Applicable only to flats/condominium and hotel developments as well as the
residential component of mixed use developments |
| 34 |
Details of PES protection / cover |
|
|
|
| 35 |
Infocomm Development Authority's (IDA) endorsement |
|
|
Applicable only to proposals involving the setting up of mobile communications monopoles. |
| Nos |
Items |
Please tick accordingly |
Remarks |
| Complied With |
Not Applicable |
| 1 |
The subject site has a legal right of way or direct access
from public road. |
|
|
All sites must have vehicular access. |
| 2 |
Access arrangement conforms with Land Transport Authority's requirements. |
|
|
|
| 3 |
Conformit with car parking requirements. |
|
|
|
| 4 |
Conformity with Good Class Bungalow Area guidelines. |
|
|
|
| 5 |
Conformity with Geylang Urban Design guidelines. |
|
|
|
| 6 |
Conformity with the MP 2003’s landuse |
|
|
|
| 7 |
Conformity with the DGP's building height |
|
|
|
| 8 |
Conformity with the MP 2003's plot ratio |
|
|
|
| 9 |
Width of structural fins within setback distance - 0.5m (max) |
|
|
|
| 10 |
Building and ancillary structures have complied with the required setback |
|
|
|
| 11 |
Basement has complied with the required setback |
|
|
|
| 12 |
Number of allowable units has been complied with |
|
|
Applicable to strata landed development only |
| 13 |
Road buffer (green and physical) has been complied with |
|
|
|
| 14 |
Site coverage has been complied with |
|
|
|
| 15 |
Communal open space provision has been complied with |
|
|
Applicable to strata landed development only |
| 16 |
Boundary wall height has been complied with the 1.8m (max) |
|
|
|
| 17 |
Retaining wall height has been complied with the 1m/1.5m (max) |
|
|
1m(max) applicable to landed housing developments;
1.5m(max) applicable to non-landed housing developments |
| 18 |
Retaining cum boundary wall height meets the 2.8m (max) |
|
|
|
| 19 |
Fencing & retaining wall have met the waterbodies requirement |
|
|
Applicable to proposals affected by waterbodies |
| 20 |
Earthworks comply with guidelines |
|
|
Applicable only to residential development |
| 21 |
Floor to floor height is within the requirement |
|
|
|
| 22 |
Basement guidelines have been complied with |
|
|
|
| 23 |
Balconies comply with the continuous perimeter opening of 40%
(min.) |
|
|
Applicable only to flats/condominium and hotel developments
as well as the residential component of mixed use developments |
| 24 |
Balcony screens comply with the performance criteria of:
- allowing natural ventilation in the balconies at all times;
and
- being able to be drawn open or retracted fully
|
|
|
Applicable only to flats/condominium and hotel developments as well
as the residential component of mixed use developments |
| 25 |
Private Enclosed Space (PES)
- Protection / covering is provided in accordance to either the
objective-based guidelines or the prescriptive guidelines (i.e.
min 2m covering)
- Height of enclosure fencing is 1m (max)
|
|
|
|
| 26 |
Provision of 2.0m planting strip has been complied with |
|
|
Except for landed housing development & periphery of
industrial development |
| 27 |
Covered Walkway
| (a) |
Soffit height is in order |
| (b) |
Width of walkway complied with the controls |
|
|
|
|
| 28 |
Prayer quantum has exceeded the 50% of the total GFA |
|
|
Applicable only to religious development |
| 29 |
Attic guidelines have been complied with |
|
|
|
| 30 |
Industry/warehouse quantum (GFA) mix is more the 60% of
total gross floor area |
|
|
Applicable to industrial/ware-house building |
| 31 |
Development Plot
| (a) |
Size (min) has been complied with |
| (b) |
Width (min) has been complied with |
| (c) |
Depth (min) has been complied with (for GCBA only) |
|
|
|
Applicable to landed housing development |
| 32 |
The provision of open space (m2) has been complied with |
|
|
Applicable to landed housing |
| 33 |
Combined frontage width of guardhouse, bin center and meter
compartment is in order |
|
|
Applicable if structure abuts the boundary |
| 34 |
The following information are provided:
|
| (a) |
Nature of the factory operations (for factory
developments with ancillary worker’s dormitory) |
| (b) |
Estimated number of workers to reside in the
dormitory |
| (c) |
Whether the workers are locals or foreigners;
and the nationality of foreign workers |
| (d) |
Whether the workers are skilled, semi-skilled
or unskilled |
|
|
|
For application with worker’s dormitory |